Specifications
Home Up Specifications Photos Apps info Further Information

 

 

 

SPECIFICATIONS
(subject to product improvement changes)
Last updated: 19 Mar 2002

Coupling Factor1:
(see graph)
-19.5 dB nominal, when probing a 50 Ohm transmission line free of standing waves.
Circuit loading effect: 1.2:1 max. induced SWR
Output impedance: Designed to drive 50 Ohm instrumentation.
Frequency Response:
(see graph)
±1.5 dB from 300 kHz to 2.7 GHz, typical.

±3 dB from less than 150 kHz, to over 3 GHz.

Max. DC blocking voltage: 50 WVDC
Cable/Connector: RG-174U, with SMA connector.
Nominal dimensions: 4" by 0.5". Cable length 32".
Pin spacing: 0.15" nominally,
measured from centerline of probe tip to centerline of pogo pin.

Footnotes:

1Coupling Factor is the conversion factor that accounts for the probe attenuation, in dB. See applications page. Custom coupling factors available on request.